Avigilon Unity/ACC 7 - Triton ULTRA Integration
A Point of Sale (POS) License from Avigilon is required for this. Integration through Triton Cloud doesn't require a POS License.
Avigilon Unity/ACC 7 Full Integration Guide Link
Integration Overview
1. Sensor Configuration (TCP Settings)
-
Navigate to: Platform Integration > TCP Settings.
-
Host: Enter your Avigilon Server IP.
-
Port:
10001(Default for POS transactions). -
Content Type: Change to Text.
-
Set String: Enter
triton.%EID@TRIGGERNAME%.
2. Avigilon Configuration (POS Transaction Source)
-
Create a new POS Transaction Source.
-
Set an Exception (e.g., "Triton_Vape") with Match Text set to
triton.Vape. -
Associate the desired cameras (including the Triton RTSP stream) to record when this text is matched.
3. Setting the Rule
-
In the Avigilon Setup tab, go to Rules.
-
Condition: POS transaction started (Select your Triton source).
-
Action: Choose desired responses, such as Start Recording or Display On-Screen Alert.
Pro-Tip:
💡 VMS Tip: By using the string
triton.%EID@TRIGGERNAME%, you only need to set up one transaction source in Avigilon. The%EID@TRIGGERNAME%wildcard will automatically send the specific event type (Vape, Tamper, Aggression), allowing you to create different rules for different event strings!